请使用支持JavaScript的浏览器!
专注于生物磁分离技术的公司
℡ 4000-520-616
℡ 4000-520-616
Bioclone/BcMag™ Quick Antibody Purification Kit/2 ml(Purify up to 10 mg IgG)/EA101
产品编号:EA101
市  场 价:¥3000.00
场      地:美国(厂家直采)
产品分类: 分子类>核酸酶类>其他>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:$150.00
品      牌: Bioclone
公      司:Bioclone Inc
公司分类:
Bioclone/BcMag™ Quick Antibody Purification Kit/2 ml(Purify up to 10 mg IgG)/EA101
商品介绍

Principle

The separation of antibodies from various biomasses can be accomplished using hydrophobic charge induction chromatography with 4-mercapto-ethyl-pyridine as the ligand. Binding is based on mild hydrophobic contact and is accomplished in near-physiological circumstances, without the use of salts. When the pH is reduced, the ligand and the antibody gain a net positive charge under mild acidic circumstances (pH 4.0-4.5).

Principle of Hydrophobic charge-induction chromatography (HCIC)

HCIC has several process advantages over more traditional antibody purification methods, such as protein A or ion exchange:

Sample preparation is reduced to scarification since feedstocks may be applied without ionic strength or pH adjustment.

Preconcentration of dilute samples is unnecessary because effective capture is accomplished even with feedstocks as dilute as 40μg of antibody per ml.

Gentle, pH-controlled elution with dilute buffer lowers the possibility of antibody aggregation at lower pH and avoids the requirement for IgG desalting or diafiltration.

Magnetic resins have significant advantages over traditional chromatography, such as column, agarose, or non-magnetic resin. The magnetic bead-based format enables rapid high-yield processing of 96 samples in about 20 minutes, achieving more than 90% purities and recoveries of more than 95% for various IgG species. When using column-based technologies, processing multiple samples in academic research labs may necessitate a significant quantity of hand pipetting. This pipetting can discourage differences in the yield of target biomolecules between experiments and people. Staff and students may require extensive training and practice to produce constant protein yields. It is due to the numerous benefits of magnetic resins, such as their ease of use, rapid experimental protocols, suitability, and convenience for high-throughput automated and miniaturized processing.

Workflow

The separation of antibodies present in complex mixtures using chromatography involves the antibodies binding the beads. After Binding, the beads are washed to remove non-antibody protein. Finally, the antibody was eluted from the beads.

Workflow of Quick antibody purification

Feature and Benefits

Efficient – recovery exceeds 85%, and purity exceeds 85%.

Fast purification – Fast and high-throughput procedure

Convenient – no columns, filters, or a laborious repeat of pipetting or centrifugation.

Amine – free buffer does not require removal or neutralization

Robust – effective for IgG subclasses that bind poorly to Protein A or G

Gentle – No harsh antibody elution conditions helps retain IgG activity

Regenerable – beads can be renewed and used for up to 3 purifications

PROTOCOL

Note:

The following protocol is an example of purifying antibodies from the serum.

The beads and sample volume can be rational Scale-up (or down).

Equipment

Item

Magnetic Rack for centrifuge tube


** Based on sample volume, the user can choose one of the following magnetic Racks

Source

•  BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

•  BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

•  BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

•  BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

Item

BcMag™ 96-well Plate Magnetic Rack.

Source

•  BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Item

Adjustable Single and Multichannel Pipettes

Item

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates / tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Eppendorf, Cat. No. 5353000529

Tube Holder PCR 96

Eppendorf, Cat. No. 022674005

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Eppendorf, Cat. No. 022674048

Smart Mixer, Multi Shaker

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR plates/tubes

** IMPORTANT! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates has to be ≥2.5mm.

Addition items are required if using 96-well micro-plates

Fisher Scientific™ Microplate Advanced Vortex Mixers

Fisher, Cat. No. 02-216-101

OHAUS Microplate Vortex Mixers

OHAUS, Cat. No. 30392160

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 800 rpm

Clear Flat-Bottom Non-Binding Assay Microplates

Items

Magnetic Rack for centrifuge tube

** Based on sample volume, the user can choose one of the following magnetic Racks

Source

BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

BcMag™ 96-well Plate Magnetic Rack

BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Adjustable Single and Multichannel Pipettes

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates/tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048

BenchTop Lab Systems, Cat. No. 5353000529

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker
 

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048
 

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR plates/tubes

! IMPORTANT ! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates has to be ≥2.5mm.

Addition items are required if using 96-well microplates

Fisher Scientific™ Microplate Advanced Vortex Mixers

Fisher, Cat. No. 02-216-101

OHAUS Microplate Vortex Mixers

OHAUS, Cat. No. 30392160

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 800 rpm

Clear Flat-bottom Non-Binding Assay Microplates

Procedure

! Important !

The following protocol is optimized for the efficient clean-up of the 3μl serum sample. The procedure may need to be optimized if an alternative reaction scale is used.

Shake or vortex the bottle to completely resuspend the magnetic beads before using.

Do not allow the magnetic beads to sit for more than two minutes before dispensing.

A.

Sample preparation

1.

Dilute whole serum with an equal volume of 2x Binding/Wash Buffer and mix well.

B.

Magnetic Particles Preparation

1.

Shake the bottle to completely resuspend the magnetic particles.

2.

Transfer desired amount of magnetic particles to a centrifuge tube (Note: 1 ml of BcMag™ Quick Antibody Purification Magnetic particles per 0.5-1 ml of whole serum is recommended. The volumes can be scaled accordingly. IgG levels in serum are usually 10-15mg/ml). Place the tube on the magnetic rack for 1-3 minutes until the supernatant becomes clear. Remove the supernatant while the tube remains on the rack.

3.

Remove the tube and resuspend the beads with 10 beads volumes of 1x Binding/Wash buffer.

C.

Sample Binding

1.

Add the washed particles from step B.4 to the diluted sample from step A1. Completely resuspend the beads and leave them at room temperature for 10-30 minutes with end-over-end rotation.

2.

Place the tube on a magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack.

3.

Place the tube on the magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack. Remove the tube from the rack and wash the particles with 10 beads volumes of 1x Binding/Wash Buffer.

4.

Repeat step 3 five times

D.

IgG Elution

1.

Remove the tube from the rack and resuspend the particles with 10 beads volumes of Elution buffer to elute IgG. Place the tube on the magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack.

Mini-scale high throughput purification

1.

Transfer 50μl beads (Step B4) to a new well of 96well PCR plate or 96-well microplates or 0.2ml PCR tube and add 20μl diluted serum from A1.

2.

Mix the beads with the sample by slowly pipetting up and down 25 times (one minute) or by vortex mixer for 5 minutes at 2000 rpm.

3.

Place the sample plate/ tube on the magnetic separation plate for 30 seconds or until the solution is clear.

4.

Discard the supernatant and wash the beads three times with 100 μl of 1x Binding/Wash Buffer using a magnetic rack.

5.

Add 50 μl of Elution buffer to elute the antibody by slowly pipetting up and down 25 times (one minute) or vortex mixer for 5 minutes at 2000 rpm.

6.

Place the sample plate/ tube on the magnetic separation plate for 30 seconds or until the solution is clear.

7.

Transfer the supernatant to a clean plate /tube while the sample plate remains on the magnetic separation plate. The sample is ready for downstream applications.

Additional information

Beads Regeneration

1.

If the bead has to be regenerated, add 10ml of 35 mM sodium phosphate; 30% n-propanol, pH 8.5 for 1 ml beads and mix the beads with the sample by slowly pipetting up and down 25 times. Place the sample plate/ tube on the magnetic separation plate for 30 seconds or until the solution is clear. Discard the supernatants.

2.

Repeat Step 1 five times.

3.

Wash the beads with 10 beads volumes of 1x Binding/Wash Buffer three times

4.

Resuspend the beads in 1x Binding/Wash Buffer and store at 4°C. The beads may be renewed three times without losing substantial selectivity.

Troubleshooting

Problem

The yield of the purified antibody is too low or undetectable

Probable Cause

Sample devoid of antibody

Suggestion

  • Ensure that the sample contains IgG by using another method, such as an ELISA or isotyping kit.

Problem

The yield of the purified antibody is too low or undetectable

Probable Cause

The antibody of interest bound to the beads

Suggestion

  • Ensure that the pH of the sample is between 8.5.

Problem

Observe multiple bands present on stained SDS-polyacrylamide gel

Probable Cause

The ratio of the beads and sample is not optimized.

Suggestion

  • Dialyze sample against 1x biding/wash buffer.
  • Optimize the ration of the beads and sample

Problem

A significant amount of antibodies was purified. However, no antibody of interest was found.

Probable Cause

The concentration of antibodies of interest is low.

Suggestion

  • Purify the antibody utilizing active affinity magnetic beads and a specific antigen.

Problem

Probable Cause

Suggestion

The yield of the purified antibody is too low or undetectable

Sample devoid of antibody

  • Ensure that the sample contains IgG by using another method, such as an ELISA or isotyping kit.

The antibody of interest bound to the beads

  • Ensure that the pH of the sample is around 8.5.

Observe multiple bands present on stained SDS-polyacrylamide gel


The ratio of the beads and sample is not optimized.
 

  • Dialyze sample against 1x biding/wash buffer.
  • Optimize the ration of the beads and sample

A significant amount of antibodies was purified. However, no antibody of interest was found.


The concentration of antibodies of interest is low.
 
  • Purify the antibody utilizing active affinity magnetic beads and a specific antigen.

Learn More

Instruction Manual

MSDS

Related Antibody Magnetic Beads →

General Reference

1.

Li M, Zhang Q, Lin D, Yao S. Development and application of hydrophobic charge-induction chromatography for bioseparation. J Chromatogr B Analyt Technol Biomed Life Sci. 2019 Dec 15;1134-1135:121850.

2.

Zhao G, Sun Y. Displacement chromatography of proteins on hydrophobic charge induction adsorbent column. J Chromatogr A. 2007 Sep 21;1165(1-2):109-15.

3.

Boschetti E. Antibody separation by hydrophobic charge induction chromatography. Trends Biotechnol. 2002 Aug;20(8):333-7.

4.

Gomes CS, Fashina A, Fernández-Castané A, Overton TW, Hobley TJ, Theodosiou E, Thomas OR. Magnetic hydrophobic-charge induction adsorbents for the recovery of immunoglobulins from antiserum feedstocks by high-gradient magnetic fishing. J Chem Technol Biotechnol. 2018 Jul;93(7):1901-1915.

5.

Hirano A, Maruyama T, Shiraki K, Arakawa T, Kameda T. A study of the small-molecule system used to investigate the effect of arginine on antibody elution in hydrophobic charge-induction chromatography. Protein Expr Purif. 2017 Jan;129:44-52.

品牌介绍


Bioclone生物磁分离技术已经在生物科学的广泛应用中引起了广泛的兴趣。
技术的优点是可以快速,简单和灵活地处理大型或微升规模的生物样品,
而无需费力地重复移液和离心操作。Bioclone已开发出广泛的产品组合,包括独特的
高品质超顺磁珠(亲和磁珠,反相磁珠,正相
磁珠,疏水相互作用磁珠,离子交换和混合模式磁珠),可用于
包括分馏在内的各种应用的蛋白质,肽,细胞,细菌,抗体,DNA / RNA和其他分子
复杂的生物样本。这些功能性磁珠(颗粒)与市售
自动磁处理器或简单的台式手动分离器兼容

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔